The belt model is one model in the library. One click on "Place from library" sets up table, belt, cabinet, signal tower and box together.
The cabinet door has yellow labels with the address (I 3.0, Q 3.1 …) and white ones with the device tag (S1, H1 …).
The control box is one housing with illuminated push buttons green, red and white and an emergency stop with a yellow collar. The emergency stop latches, on the door and on the box.
Labels and assignment field show address and name, under clear acrylic.
S1 and S3 are normally closed and read 1 at rest, as does the light barrier.
The inductive sensors detect a part up to 5 mm in front of the cap.
The signal tower sits on port 1 of the IO-Link master. In the I/O list it shows as one row QW13 instead of 16 single bits.
Distributed I/O
A distributed station with IO-Link master and IO-Link devices sits in the local control box. The slots match the PLC project.
The IO-Link master has its own start address for outputs.
The PLC console sorts by module group, per station with cards and I/O start. If addresses overlap, the row turns red.
Picking up work pieces
A work piece can be picked up with the mouse and placed elsewhere, even while the plant is running.
A held part floats above the highest surface below it and no longer slides under a higher belt.
Development
The development room looks like a program: menu bar, tree on the left, library on the right, properties.
The library shows only finished models, sorted by model.
While dragging, the plate shows all grid points. Every device takes its start address from the device file.
Push buttons, switches and toggle switches can be clicked in the hall. The toggle switch latches on one side and is momentary on the other.
Controls and editor
The ST editor suggests variables with Ctrl+Space.
The workbench opens on the side you come from.
The manual help button also finds signals with an underscore in the name.
Steam build
The Steam build has no AI interface.
"Device format and rules" lies as text next to the exe.