Playtest 8: power and safety, current model, handbook chapter 6

Baukiste Playtest · published · build 25933126

Playtest 8: power and safety like in a real control cabinet, current model based on datasheets, new handbook chapter "Power and safety", button press in the library, conveyors and sensors extended, many fixes. Based on Playtest 7 from October 3.

1. Power and safety

Power from the schematic

  • Main switch, circuit breaker per location, motor protection switch, contactor, reversing contactor and power supply as real devices in the control cabinet
  • Easy mode: whatever you don't place yourself, the game adds automatically
  • Reversing contactor with interlock: forward and reverse never pull in at the same time

Current model

  • Motors draw current according to their datasheet: idle, load, start-up and stall
  • The motor protection switch trips along its characteristic curve, e.g. when a drive stalls
  • You set the current on the motor protection switch yourself; the right value is the rated current

Safety chain

  • Safety relay with reset and feedback circuit
  • Emergency stop and safety door with two channels, a cross-circuit is detected
  • The emergency stop safely switches off the valves, the cylinders vent
  • The enable signal of the safety relay reaches the PLC as an input

Load groups and zones

  • Indicator lights have their own load group and stay on during an emergency stop
  • Every location with its own emergency stop gets its own safety relay
  • An emergency stop only stops its own location, the emergency stop on the main cabinet stops everything

2. Handbook

New chapter 6 "Power and safety" (German and English)

  • From the main switch to the two-channel emergency stop
  • Practice faults to try out, e.g. motor protection set too low, limit switch forgotten, cross-circuit

Reworked

  • First steps right at the start: drawing conveyors, picking parts, rotating, moving, using windows
  • Text no longer breaks in the middle of a sentence
  • Devices are named by type and technical data, not by manufacturer or order number, also in the schematic

3. Button press and development

Button press in the library

  • The complete station as one device, plus its building blocks: table, conveyor, gripper, slide and press tower
  • Controllable with the practice PLC, with TIA Portal and S7-PLCSIM Advanced, or with CODESYS

Development hall

  • Testing in the hall: set up a design, test conveyor, practice or external PLC, slow motion, history, signal check, undo
  • Your own devices with their own mounting slots, a table with a 25 mm grid for free placement
  • Model check before import: dimensions, units, axes, origin and VR load
  • Import from other programs, export to RobotStudio

4. Conveyors, sensors and stations

Conveyors

  • Loops with diverter and merge, flap and stopper, parts turn along in curves
  • Several motors per conveyor with zone colors, drive selectable per cell
  • The workbench shows the equipment identifier and attached devices, light barriers can be moved with arrows

Sensors and displays

  • New: capacitive sensor, color sensor with teach-in, roller conveyor scale
  • Signal tower with RGB segments and blinking
  • Displays show unit and position correctly

Spawners

  • Controlled by the game or by the PLC, part types from material and color
  • Parts with conditions, so every station can be tested on its own

Stations

  • Cutter: cutting from the blank, with corner head and free-form head
  • Welding station: sealing a tray, with spot head and seam head
  • Measuring station: measuring bench and touch probe
  • Filling station: volume by hand calculation, with auto and dosing filling head


Retired: flashing light, indicator lamp, sample bottle

5. PLC connection

  • PLCSIM Advanced: one address per signal in the PLC console, like on a real terminal. You set name and address yourself, both end up in the tag table.
  • S7-PLCSIM Advanced: the guide in the package walks you step by step through your own TIA project. The game writes the tag table for it, and for TIA and PLCSIM themselves the guide points to the Siemens manuals. No ready-made project template is included.
  • CODESYS via Modbus: inputs from %IX0.0, no coils needed anymore, mapping file for import
  • First start: OPC UA 4840 and Modbus 502 as defaults

6. Schematic

  • Local control box with its own sheet and matching location number
  • Station, analog, card and assembly sheets show what is in the plant
  • One sheet per safety relay, load groups on the output card

7. Interface and fixes

  • Hint on first start: the game is in development, and where to report bugs
  • Height levels switched off
  • When you switch the language, messages, hints, rejection reasons and fault texts now switch too
  • Saves in the old cabinet format (operator devices still on the former front slots) are no longer converted. The game tells you clearly instead of creating a box without a machine.
  • Fixed: a sheet-metal variant of the feeder produced no parts

8. Known issues

  • Devices in the door and on the roof of the main cabinet do not appear on any schematic sheet yet.