Important if you already have a CODESYS program over Modbus

  • PLC addresses now stay fixed. After the update, press "⤓ Write GVL" once in the PLC console and paste GVL_Modbus.gvl into CODESYS – from then on no address moves, not even when you remove or rebuild devices. New addresses are only assigned on request ("Renumber", with a confirmation that lists every change).

Modbus and CODESYS

  • "CODESYS (Modbus TCP) – recommended": IP/host and port are visible, port 502 is preset. An empty or mistyped port field connects to 502 instead of 4840. "localhost" now also connects to CODESYS.
  • The PLC console shows each signal's Modbus address (coil:0) to type in, and next to it the IEC address from the CODESYS I/O image (%IX24.0) – the same everywhere (console, workbench, circuit diagram). The four numbers for the Modbus device are shown above the cards.
  • An address already used by another sensor, or outside 0 to 65535, is rejected with a reason. Two lamps or valves on one output are allowed and shown as "parallel with …".
  • The CODESYS guide in the package now starts with "Update device" in case the template shows a red ? on a newer CODESYS.

Language and controls

  • The language selector in the manual (top right) is a menu with every language and shows how complete it is. Your own translation (<language>.po) in the "sprachen" folder of your save data appears there without an update.
  • When you switch language, the open PLC console changes completely and immediately – no restart.
  • The PLC console shows the unit after every decimal value ("12.5 mm", "50 %").
  • Workbench: one click on a NONE card opens the selection, even if the mouse moves a few pixels.
  • The camera no longer keeps turning when you release the mouse button over a window.
  • In the menu and on the manual's start page: Discord – help and community.

Simulation and circuit diagram

  • At the inflow you set the volume flow in L/min (4.70 to 141.13) instead of a level rate. Old saves load with the same amount per time.
  • Workpieces travel exactly at the set speed over long belts and smoothly over curves, switches, merges and the ramp.
  • The seam welding head only lowers over sheet metal and at joints; over air it stays at travel height.
  • Circuit diagram: every PLC card is visibly connected to its supply (L+/M with the real terminal numbers); the analog output card shows its four terminals.
  • A self-built device carries the class from its manifest in the diagram ("bmkKlasse": "-P" → -P1).